thermostat_setback_value_updated – gets sent if a thermostat setpoint state value has been changed
				
					{
    event = "thermostat_setback_value_updated",
    node_id = 2,
    channel_id = 0,
    override_type = "no_override",
    mode = "frost_protection"
}

{
    event = "thermostat_setback_value_updated",
    node_id = 2,
    channel_id = 0,
    override_type = "temporary_override",
    mode = "custom_value",
    value = 1.4
}				
			
fields type required description
event string + type of an event
node_id int + a unique id of a ZWave device within a Zwave network
channel_id int +
override_type string + actual override type
mode string + actual mode
value float value is not required for modes “frost_protection” and “energy_saving_mode”. Min: -12.8, max: 12.0 for mode “custom_value”. If mode is “unknown” value advertises actual number state of setback (see zwave specification).